50-2  IMSA

 

 

 

COPPER TYPE: STRANDED TINNED COPPER
CHARACTERISTICS: 2 CONDUCTORS INSULATED WITH POLYETHYLENE, TWISTED, SHIELDED WITH ALUM. MYLAR AND JACKETED WITH POLYETHYLENE
APPLICATION: TRAFFIC SIGNAL SYSTEMS

 

PART # AWG # COND. STRANDING INSULATION THICKNESS JACKET THICKNESS NOMINAL O.D.
98021250-2 12 2 19 .030 .030 .365
98021450-2 14 2 19 .030 .030 .340
98021650-2 16 2 19 .030 .030 .295
98021850-2 18 2 19 .030 .030 .280

** COLOR CHART-BLACK AND CLEAR

 

 

 

                          51-5  IMSA

 

COPPER TYPE: STRANDED TINNED COPPER
CHARACTERISTICS: SINGLE CONDUCTOR INSULATED WITH PVC AND NYLON, THEN JACKETED WITH A LOOSE TUBE PVC JACKET
APPLICATION: LOOP DETECTOR CABLE

 

PART # AWG # COND. STRANDING INSULATION THICKNESS JACKET THICKNESS NOMINAL O.D.
98011451-5 14 1 19 .015 PVC
.004 NYLON
.030 .250

 

** ALSO AVAILABLE WITH POLYETHYLENE LOOSE TUBE JACKET

** SMALLER NOMINAL O.D. ALSO AVAILABLE